What to Send for an Accurate Metal Panel Quote: A Checklist for GCs and Architects

Bid day is not the time to discover that a metal panel number left out the column covers, assumed the wrong joint or priced PE core when the drawings say FR. Most quote problems come from missing information, not bad math. This checklist covers what a fabricator needs to price Sure-Panel® ACM, aluminum plate and column cover scopes accurately, and what each item changes in the number.
Why the details change the price
Sure-Panel® quotes from drawings because project pricing depends on the system, panel size, core, finish and schedule. Two walls with the same square footage can price very differently if one is a large, flat rainscreen field and the other is full of corners, soffits and radius panels. For a primer on cost drivers, see our ACM cost per square foot guide.
The core checklist
1. Drawings
Elevations showing every panel area, with dimensions.
Sections and details at the base, parapet, window heads, sills, jambs, soffits and transitions.
Plans and reflected ceiling plans for soffits, canopies and column locations.
Specification section, if one is written (for example 07 42 13 for ACM rainscreen or 05 58 13 for column covers).
If the design is early, schematic elevations with approximate square footage are enough for a budget number. Detailed drawings get you a firm one.
2. Square footage and quantities
Panel square footage by system and by color.
Number of column covers by type, with dimensions.
Linear footage of trims, copings or extrusions, if they are in scope.
3. The system
Name the joint system for each area. Sure-Panel® offers:
ACM dry joint rainscreen: rout-and-return panels on the proprietary Sure-Panel® aluminum extrusion, with no caulking or exposed fasteners.
ACM wet seal: rout-and-return panels on mechanically fastened clips, with joints sealed with silicone-based caulk.
Sure-Panel® Quick-Snap™: a concealed-fastener system for ACM and aluminum plate panels, designed for fast, clean installation, with concealed fasteners and no exposed screw heads.
Column covers with hairline, reveal or caulk joints.
If you are not sure which system fits, our rainscreen vs. wet seal guide explains the difference.
4. Material, thickness and core
ACM: 3, 4 or 6 mm, FR or PE core. FR is the usual specification. If a manufacturer is specified (Alucobond, Alfrex, Reynobond, Etalbond or ALPOLIC), say so.
Aluminum plate: .063" to .250", or stainless steel in 18, 16, 14 or 11 gauge. Note whether perforation is required.
Column covers: painted or anodized aluminum .090" to .125", 4 or 6 mm FR ACM, or 16 gauge 304 or 316 stainless.
5. Finish and color
Finish type: PVDF to AAMA 2605 or 2604, anodized, or for column covers powder coat, brushed stainless, mill or primed.
Color names or numbers, and whether any are custom.
Accent colors for rainscreen reveals, if the design uses them.
6. Panel sizes and layout
Note any panel module the design requires. Sure-Panel® ACM and plate panels go up to 59 by 193 inches. Larger panels or unusual modules affect yield and price.
7. Column cover specifics
For each column type, send shape and size, height, quantity, joint type, material and finish, and any capitals, bases or rings. Remember: the maximum one-piece length is 15 feet, and taller covers are stacked sections with hairline or butt joints.
8. Schedule and scope split
Required delivery date and whether phased deliveries are needed.
Whether shop drawings are included. Typical fabrication lead time is 3 to 4 weeks, or about 6 to 8 weeks when drafting (shop drawings) is included.
What is in the fabrication scope and what belongs to the installer, such as substructure, sheathing, air and water barriers and field labor.
Ship-to location. Panels are crated in Burnsville, Minnesota, and shipped nationwide.
Common gaps that slow quotes down
A single total square footage with no split by system or color.
Soffits, canopies and column covers that appear only on sections or plans.
"Manufacturer's standard" finish with no color.
No indication whether alternates are allowed. Substitution decisions stay with the design professional.
Column cover heights missing, so nobody can tell whether a cover needs a stack joint.
Details that show a panel system different from the one named in the specification. Point out the conflict, or tell us which one governs.
What happens after you send it
Once the scope is clear, we price it from the drawings. After award, the shop prepares shop drawings that lay out each elevation panel by panel and confirm joint locations, dimensions and attachment. Once those are approved, panels are CNC-routed, returned, prepared for their system, labeled to the shop drawings and crated for delivery.
Quote checklist FAQ
Can you quote from schematic drawings? Yes, for a budget number. A firm quote needs elevations, details, the system, material and finish.
Do you need the specification? It helps. Sure-Panel® specifications and details are on our Specs & CAD page if you need to write one.
Who prepares the shop drawings? The CNC Metalcraft® team in Burnsville, MN prepares shop drawings, fabricates and crates the panels.
Send your drawings for a quote
Email drawings and the checklist items above to sales@sure-panel.com, call (952) 938-3356 or use the contact page. You can also request a quote through CNC Metalcraft®.
Related articles
How to Specify Metal Column Covers: A Section 05 58 13 Checklist
Column Covers Taller Than 15 Feet: How Stacked Sections Work
Retrofit Column Covers: How to Clad Existing Columns in a Renovation
PVDF, Anodized or Powder Coat? Choosing a Finish for Metal Panels and Column Covers
Interior vs. Exterior Column Covers: Choosing Joint, Material and Finish




Comments