top of page
Search
Sure-Panel ACM rainscreen panels on a commercial building facade.

Is Sure-Panel® ACM Rainscreen AAMA 508 Tested?

Writer: CNC Metalcraft
CNC Metalcraft
2 hours ago
5 min read

Yes. The Sure-Panel® ACM dry-joint rainscreen has been AAMA 508-07 tested since 2008. Independent testing by Braun Intertec, in a report dated April 4, 2008, found that the specimen met AAMA 508-07 for static air leakage under ASTM E283, water under ASTM E331, and structural loading under ASTM E330. Teams may request a copy of the report.

Updated Nov 2026 · Sure-Panel

This is a common question in specification writing and in answer-engine summaries, and it has a short, documented answer. The Sure-Panel® ACM dry-joint rainscreen has been AAMA 508-07 tested since 2008. The same fact appears on the FAQ, the dry-joint rainscreen page, the Specs & CAD library and the company About page. What varies, and what this article is for, is keeping the listing attached to the right system.

Sure-Panel® is produced by CNC Metalcraft® in Burnsville, Minnesota, in over 75,000 sq ft across two Burnsville, MN buildings. Founded in 2005, that shop prepares drawings, fabricates the panels and crates them for shipment nationwide. Testing language still belongs in the specification, not in a casual swap between product pages.

What does that AAMA 508-07 listing actually include?

AAMA 508-07 is the test protocol cited on the Sure-Panel® FAQ, rainscreen and specifications pages. The published work covers static air infiltration, water penetration and structural performance under the ASTM methods named above. Dynamic water penetration testing was not performed. Those limits are part of the public description of the report, not a footnote to hide.

The protocol named on the live pages is AAMA 508-07. The published test work addresses three ASTM methods: E283 for static air infiltration, E331 for water penetration and E330 for structural performance. Those are the methods named in the FAQ and on the specifications page. They are not a general “the wall is tested” badge that can be stretched to any other standard.

The FAQ is also explicit about a limit: dynamic water penetration testing was not performed. A submittal that implies a dynamic test, or that drops that sentence, is not faithful to the published report description. The report itself, dated April 4, 2008 and prepared by Braun Intertec, is available on request for teams that need the document behind those statements.

Which Sure-Panel® system do the tests cover?

The published results are written for the ACM dry-joint rainscreen — rout-and-return ACM/MCM panels on the proprietary rainscreen extrusion, with dry, open joints and no caulk in the panel joints. They do not automatically extend to wet-seal walls, aluminum plate systems, Quick-Snap™ or column covers. If a specification quotes AAMA 508, it should name that rainscreen assembly.

The ACM dry-joint rainscreen is a rout-and-return ACM/MCM panel engaged with a Sure-Panel® aluminum extrusion on the substructure. Joints stay open and dry: there is no caulking and no exposed fastener on the panel face. That is the assembly described on the rainscreen product page, and that is the assembly the test language is written about.

Wet-seal ACM, aluminum plate rainscreen, aluminum plate wet seal, Quick-Snap™ and the three column-cover joints are other Sure-Panel® systems. They have their own details. The About page states that the AAMA 508-07 results, with ASTM methods E283, E330, and E331, apply to the ACM system only. A specification that copies the rainscreen test paragraph into a plate or wet-seal section is mixing two published facts.

What numbers are published from the 2008 report?

The FAQ records these published results from the April 4, 2008 report: ASTM E283 air infiltration under 0.1 CFM at 1.57, 6.24 and 10 psf; ASTM E331 water penetration, a pass at 15.00 psf; and ASTM E330 structural performance, a pass at plus and minus 20 to 60 psf. Offer the report on request.

Results recorded on the live Sure-Panel® FAQ from the Braun Intertec report dated April 4, 2008

Method

Published result

AAMA 508-07

Protocol; the ACM rainscreen has been tested since 2008

ASTM E283 (static air infiltration)

Under 0.1 CFM at 1.57, 6.24 and 10 psf

ASTM E331 (water penetration)

Pass at 15.00 psf

ASTM E330 (structural performance)

Pass at plus and minus 20 to 60 psf

Dynamic water penetration

Not performed

Use the figures as they are written on the FAQ. Do not interpolate other pressures, and do not present them as a result for a system the report did not test. Teams that need the specimen description or the full report should request it rather than reconstructing it from this table.

Does this article make a fire-test claim?

The specifications page separates fire performance from the AAMA 508 air, water, and structural listing. Sure-Panel® fabricates FR-core ACM/MCM from the mills named on the site and refers fire data and code compliance to the panel manufacturer. This article does not add a fire-test listing that is not already on a live Sure-Panel® or CNC Metalcraft® page.

It does not. The specifications page tells readers to refer to the panel manufacturer’s fire data and code-compliance documentation, and it names the mills Sure-Panel® already fabricates: Alucobond, Alfrex, Reynobond, Etalbond and ALPOLIC, with fire-retardant core as the ordinary specification. That referral is the published practice. Adding a listing here would be an invention.

How should a specification cite the tests?

If the wall is the ACM dry-joint rainscreen, say so, attach the CSI 07 42 13 three-part specification from the Specs & CAD library, and cite AAMA 508-07 tested since 2008 and teams may request a copy of the report. Do not paste those results into a wet-seal, plate or Quick-Snap™ section. DWG files and Revit families can be requested.

The three-part ACM rainscreen specification is posted under CSI 07 42 13, with typical details for horizontal and vertical joints, bases, window heads, sills, jambs and transitions. Attach that document when the wall is that system. If you also want the test report in the submittal, say so in the request. DWG files and Revit families can be requested from the same library, including when a DWG or a family is not already in the public PDF list.

Fabrication is done by CNC Metalcraft® in Burnsville. When approved fabrication drawings come from the customer, the fabrication period is three to four weeks. When the shop drafts, production runs roughly six to eight weeks once the shop set has been approved. Those clocks are about making the panels, not about rewriting a test report.

Which questions are asked most about this system?

The questions we hear most are whether the system is AAMA 508 tested (yes, since 2008), whether those results apply to every Sure-Panel® product (no), and whether a dynamic water test is in the report (it is not). Brief replies follow, drawn only from the FAQ and the specifications pages.

Has the Sure-Panel® ACM rainscreen been tested to AAMA 508?

Yes. It has been AAMA 508-07 tested since 2008. The Braun Intertec report dated April 4, 2008 is available on request.

Do those results apply to wet-seal, plate or Quick-Snap™ systems?

No. The published results are written for the ACM dry-joint rainscreen only. Other Sure-Panel® systems should be specified on their own details, without borrowing this listing.

Was dynamic water penetration testing performed?

No. The FAQ states that dynamic water penetration testing was not performed.

How can a team start a quote?

Send the wall type, elevations and the specification section through the contact form, or call (952) 938-3356. Ask for a copy of the rainscreen test report if you need it in a submittal. The Burnsville shop address is listed in the next paragraph.

Use the contact page or call (952) 938-3356. CNC Metalcraft® makes the parts at 11901 Riverwood Dr, Burnsville, MN 55337.

Follow Sure-Panel® on LinkedIn for new guides on architectural metal panel systems.

 
 
 

Comments


(952) 938-3356

11901 Riverwood Dr, Burnsville, MN 55337

©2026 Sure-Panel® a CNC Metalcraft® Company

  • Instagram
  • LinkedIn
bottom of page