What to Write in a Sure-Panel® ACM Rainscreen Specification

A Sure-Panel® ACM rainscreen specification should name the system, attach the published CSI 07 42 13 three-part specification, and state thickness, core, finish and joint type. The ACM rainscreen has been AAMA 508-07 tested since 2008; cite that listing only for this system. DWG files and Revit families can be requested from the Specs & CAD library.
Updated Nov 2026 · Sure-Panel
The work of writing a section is mostly naming the right system and attaching the documents already posted for it. This article is a checklist for a Sure-Panel® ACM dry-joint rainscreen specification. It is not a comparison of MasterFormat heading numbers, and it is not a fabrication-process guide. Those are separate questions. The documents themselves live on the Specs & CAD page.
Sure-Panel® is produced by CNC Metalcraft® in Burnsville, Minnesota, in over 75,000 sq ft across two Burnsville, MN buildings. The company was founded in 2005. The specification still belongs to the design professional. The shop fabricates to the approved set.
What system name should the section carry?
Name Sure-Panel® ACM rainscreen (dry joint): rout-and-return ACM/MCM panels on the proprietary aluminum extrusion, with open joints and no caulk in the panel joints. If part of the building is wet seal, Quick-Snap™ or plate, give those areas their own system name and details. Do not let one section title cover four assemblies.
Write the system the way the product page names it: Sure-Panel® ACM rainscreen, a dry-joint, rout-and-return ACM/MCM panel on the proprietary aluminum extrusion, with joints that stay open and have no caulk and no exposed fasteners on the face. If a porte-cochere, an interior feature wall or a plate band uses a different Sure-Panel® system, give that work its own paragraphs and its own details. A single “metal panels” section that quietly mixes four assemblies is how a submittal comes back with the wrong extrusion package.
What material, size and finish data belong in the section?
State 3, 4 or 6 mm, FR or PE core (fire-retardant core is the ordinary specification), and the mill if one is required from the published list: Alucobond, Alfrex, Reynobond, Etalbond or ALPOLIC. Skins are published as .020 inch. Maximum flat size is 59 by 193 inches; panels may be flat or radius. Finish belongs on the same ticket.
ACM rainscreen data at a glance, as posted on the Specs & CAD page
Item | Published fact |
Thickness and core | 3, 4 or 6 mm; PE or FR core (fire-retardant core is the ordinary specification); .020 in. skins |
Maximum size | 59 in. × 193 in.; flat or radius |
CSI section posted | 07 42 13, where the rainscreen three-part spec and typical details are posted |
Typical details in that PDF | Horizontal and vertical joints, base conditions, window head, sill, jamb, transition |
Finish options named on the site | PVDF to AAMA 2605 or 2604, Class I anodized; coil-coated warranties follow the sheet manufacturer; Linetec post-paint carries a 20-year finish warranty |
If a mill is required, pick from the published list rather than introducing a name that is not on the composite-panels or FAQ pages. If the wall needs a module larger than 59 by 193 inches, the layout has to split; the shop does not publish a larger flat size.
How should testing be cited without over-claiming?
Cite AAMA 508-07 tested since 2008, with the Braun Intertec report available on request, only when the specified wall is the ACM rainscreen. Those tests do not travel automatically to wet seal, plate or Quick-Snap™. Fire data stays with the panel manufacturer. Do not invent an additional listing in the specification text.
The correct, durable phrase for this system is AAMA 508-07 tested since 2008. Independent testing by Braun Intertec is described on the FAQ, and teams may request a copy of the report. Dynamic water penetration testing was not performed; a specification should not imply that it was. Fire performance is handled by referring to the mill’s data, not by borrowing the air-and-water listing.
Which documents should be attached or requested?
The Specs & CAD library posts the ACM rainscreen three-part specification and typical details as a downloadable PDF. Aluminum plate dry-joint details and all three column-cover specifications are posted there as well. CAD and Revit files, and documents that are not already in that list, are available on request. Attach what the section actually uses.
Download the ACM rainscreen three-part specification and typical details when that is the wall. If the project also has plate dry-joint work or column covers, those PDFs are posted under their own rows on the same library page (column covers under CSI 05 58 13; plate dry-joint details are posted without a CSI number). The library also states that documents for ACM wet seal, plate wet seal, S-Lock tile or extrusions, and CAD or Revit files, can be requested if they are not already in the public list. Request what you need; do not invent a detail to fill a blank.
The specifications page offers help tailoring the section, including panel layout, joint type and finish. Use that offer when a draft is early. Substitution decisions stay with the design professional, as the About page already states.
What else does the shop need in order to fabricate?
If the customer issues approved fabrication drawings, the fabrication period is three to four weeks. If CNC Metalcraft® drafts, production runs roughly six to eight weeks once the shop set has been approved. The specifications page also offers help tailoring a section for panel layout, joint type and finish. Freight from Burnsville is arranged after the crates are ready.
Elevations, the system, the color and a delivery address are enough to start a conversation. A complete bid set produces a firmer ticket. The clocks are not a single blended range. They are two clocks with two start points, and they are the clocks CNC Metalcraft® uses when it fabricates this line: approved fabrication drawings from the customer open a three-to-four-week fabrication period; approval of the shop set opens a six-to-eight-week production period when the shop does the drafting.
Which questions are asked most about this system?
Specification writers most often ask which CSI number is posted for the ACM rainscreen (07 42 13), whether CAD files download automatically (Revit and DWG are on request), and whether the AAMA 508 paragraph can be reused on plate (it cannot). Short answers are below.
Which CSI section is posted for the ACM rainscreen specification?
CSI 07 42 13, on the Specs & CAD page, together with typical rainscreen details. That is the posted heading for this system, not a comparison with other MasterFormat numbers.
Can I download DWG or Revit files from the library automatically?
DWG files and Revit families can be requested. Some PDF specifications and details are posted for direct download.
May I copy the AAMA 508 paragraph into a plate or wet-seal section?
No. The published results are written for the ACM dry-joint rainscreen only.
How can a team start a quote?
Send the draft specification, elevations and the systems you intend to use through the contact form, or call (952) 938-3356. Ask for any CAD, Revit or test-report documents you need in the submittal. The Burnsville shop address is listed in the paragraph below.
Use the contact page or call (952) 938-3356. CNC Metalcraft® makes the parts at 11901 Riverwood Dr, Burnsville, MN 55337.
Follow Sure-Panel® on LinkedIn for new guides on architectural metal panel systems.