Hotel work usually splits into three Sure-Panel® systems: an ACM dry-joint rainscreen on the main facade, wet-seal ACM at a porte-cochere or canopy, and Quick-Snap™ or hairline-joint column covers in the lobby. Brand-exact PVDF colors, including custom colors, and large panels up to 59 by 193 inches, are the published reasons teams specify the line for hospitality.

Updated Nov 2026 · Sure-Panel

A hotel reads as a brand from the curb and again in the lobby. The hospitality page already recommends a split: ACM dry-joint rainscreen on the facade, ACM wet seal at the porte-cochere or canopies, and Quick-Snap™ or hairline-joint column covers inside. This article turns that split into specification language, using only published system facts. It does not name projects or owners.

Sure-Panel® has fabricated rainscreen facades for hotels in Minnesota, Wisconsin and Ohio, in finishes that run from layered blacks to custom reds. CNC Metalcraft® produces this hospitality work in Burnsville, Minnesota, in over 75,000 sq ft across two Burnsville, MN buildings. Finished crates ship nationwide.

What belongs on the hotel facade?

The recommended facade system is the ACM dry-joint rainscreen: rout-and-return panels, open joints, no caulk line, and AAMA 508-07 tested since 2008. Large modules, up to the published 59 by 193 inch limit, reduce the number of joints on a street elevation. Confirm the core (FR is usual) and the color path on the same ticket.

Open dry joints give a crisp line with no caulk to maintain on the main wall. The system behind that look is the Sure-Panel® ACM rainscreen, which has been AAMA 508-07 tested since 2008. Attach the CSI 07 42 13 three-part specification and typical details from the Specs & CAD library. Name 3, 4 or 6 mm and the core; fire-retardant core is the ordinary specification. Fire data remains with the panel manufacturer.

The published maximum panel size, 59 by 193 inches, is useful on a long street elevation because it can reduce the number of joints. It is also a hard limit. Layouts that exceed it have to be split, not hoped through.

What belongs at a porte-cochere or canopy?

Porte-cocheres and canopies are listed for ACM wet seal, where joints are sealed with backer rod and silicone-based caulk. That is a different assembly from the dry-joint rainscreen. Do not copy AAMA 508 language onto a wet-seal canopy section. If the canopy uses plate instead, specify the plate wet-seal system and its own details.

A canopy is not automatically the same system as the facade, even when the color matches. The hospitality page points those areas to ACM wet seal. That assembly uses rout-and-return panels on mechanically fastened clips, with joints sealed in the field. If the design uses plate at a canopy instead, switch to the plate wet-seal system and request any details that are not already posted. In either case, keep the rainscreen test paragraph off this section.

What belongs in the lobby and other interiors?

The hospitality page recommends Quick-Snap™ or hairline-joint column covers for lobby and interior features. Quick-Snap™ hides fasteners on feature walls, elevator surrounds, soffits and ceilings. Hairline covers use an internal key-slot so only a thin line shows, which is the usual interior joint. Name the interior system instead of extending the facade section into the lobby.

Hospitality system split, as recommended on the live hotel and hospitality page

Area

Recommended Sure-Panel® system

Main facade

ACM dry-joint rainscreen

Porte-cochere and canopies

ACM wet seal

Lobby and interior features

Quick-Snap™ or hairline-joint column covers

Quick-Snap™ is a concealed-fastener system for ACM/MCM and aluminum plate, with adhesive-backed clips that snap into wall-mounted extrusions. The product page lists feature walls, elevator interiors and surrounds, soffits, ceilings and column covers among its interior uses. Hairline-joint covers hide fasteners and sealant behind an internal key-slot, which is why they are a common lobby choice. Write a short interior section, or a column-cover section under CSI 05 58 13, rather than stretching the facade rainscreen language into the reception area.

How should brand color be specified on a hotel?

Brand-exact color in PVDF finishes, including custom colors, is a published hospitality reason for the product. Coil-coated warranties follow the sheet manufacturer; A Linetec post-painted finish is published with a twenty-year finish warranty. Review custom or metallic samples in light that resembles the facade or the lobby, not only on a desk.

Custom reds and tight black palettes are typical hospitality requests, but the ticket still has to say whether the finish is a coil-coated PVDF color to AAMA 2605 or 2604, or a Linetec post-paint. Those paths do not share a warranty letter. Approve samples for the facade and for any interior metal that must read as the same color. Standard colors are available when a custom formula is not required.

DWG files and Revit families for the rainscreen and for column covers can be requested from the same library if they are not already in the public PDF list. Ask for them early enough that the interior and canopy details are in the set before shop drawings start, especially when a lobby feature wall and a facade share a color but not a system.

How should opening-day schedules be written?

When the customer supplies approved fabrication drawings, allow three to four weeks for fabrication. When the shop prepares the set, production runs roughly six to eight weeks after approval. Put those clocks, plus freight from Burnsville, on an opening-day schedule. A blended range that omits the start date should not be used.

Opening dates are unforgiving, which is why hospitality teams ask about lead time early. Use the two correct clocks, plus a freight estimate from Burnsville after the crates are ready. Do not write a single blended number that starts at the wrong approval. The shop, founded in 2005, can support a hotel schedule; it cannot invent a third clock to recover a late color or a late drawing set.

The fabricator’s overview of ACM/MCM work is CNC Metalcraft® composite panel systems. Keep the Sure-Panel® hospitality and system pages in the project manual when the question is which system belongs on which part of the hotel.

Which questions are asked most about this system?

The questions we hear most are which system belongs on the facade (dry-joint ACM rainscreen), what to use at a canopy (wet seal, as recommended), and whether lobby column covers can be specified from the facade section (no; use Quick-Snap™ or a hairline cover). Short answers are below.

Which system should we specify on the main hotel facade?

The hospitality page recommends the ACM dry-joint rainscreen, which has been AAMA 508-07 tested since 2008. Attach the CSI 07 42 13 specification and typical details.

What system is recommended at a porte-cochere or canopy?

ACM wet seal, as listed on the hospitality page. Do not reuse the rainscreen test listing on that section.

Can lobby column covers be specified in the facade section?

They should be specified as Quick-Snap™ or as hairline-joint column covers, which is the interior recommendation on the hospitality page, rather than as an extension of the facade rainscreen.

How can a team start a quote?

Send facade, canopy and lobby elevations, with the system, color and delivery city for each area, through the contact form, or call (952) 938-3356. Say whether drafting is in shop scope. The Burnsville address is listed in the paragraph below.

Use the contact page or call (952) 938-3356. CNC Metalcraft® makes the parts at 11901 Riverwood Dr, Burnsville, MN 55337.

Follow Sure-Panel® on LinkedIn for new guides on architectural metal panel systems.

 
 
 

Comments


(952) 938-3356

11901 Riverwood Dr, Burnsville, MN 55337

©2026 Sure-Panel® a CNC Metalcraft® Company

  • Instagram
  • LinkedIn
bottom of page